Abstract
The modification of a new design in orthosis usually has its clinical indication. In this study, a low temperature thermoplastic AFO was designed in anterior leaf type, called MIT (metatarsal into tibial )AFO, basically to meet the need of indoors barefoot walking in Taiwan. It could be easily molded and remolded to fit the foot, as well as to adjust the position of foot and ankle.Sixty-eight patients with acute hemiplegia were fitted with this MIT-AFO during ambulation training, 46had good fitting (67.6%), 15 in fair grade (22.1%), and 7 in poor grade (10.3%). Two patients were observed to have ankle clonus, 4 patients experienced breakage or tear of the AFO with in 4 weeks. The gait characteristics were measured in 6 chronic hemiplegia to compare the effect of MIT-AFO with posterior leaf AFO (Teufel style). Their gait pattern did impove by AFO fitting, especially from the foot pressure distributions, but no significant difference between the patients with two AFOs was found.